Abstract

Background & Aims: Today, different imaging techniques have been studied in the reading of radiationsensitive polymer gels dosage. Due to limitations of imaging techniques such as magnetic resonance imaging (MRI) and computed tomography (CT), ultrasound techniques are proposed for dose-dependent parameter extraction. In this study, using MAGIC-f (methacrylic and ascorbic acid in gelatin initiated by copper with added formaldehyde) polymer gel and megavoltage radiation energy, the dose-dependent parameters of speed of sound and broadband ultrasonic attenuation (BUA) were evaluated. Methods: MAGIC-f polymer gel was irradiated with 1.25 MeV of Cobalt-60 and received a uniform dose in the range of 0 to 60 Gy in 2 Gy steps (2% accuracy). After calibration of ultrasound system with 500 kHz frequency, the parameters of speed of sound and BUA coefficient of exposed polymer gel samples were measured. Based on the dose-response curve, the ability of the ultrasound parameters in reading the absorbed dose was investigated. To evaluate the reasonable time interval with the most sensitive reading of the ultrasound method, samples were studied 3, 24, 36, and 48 hours after irradiation. To study the temperature readings, the gel samples irradiated at 5, 15, and 25 °C were studied. Results: The relationship of variation of speed of sound and attenuation coefficient and quality index (QI) with absorbed dose 3, 24, 36, and 48 hours after irradiation of gels are shown with a fourth-order polynomial fit. The results show that ultrasonic parameters have higher sensitivity 24 hours after irradiation. The sensitivity of dose-speed of sound and attenuation curve were 50 cm/s and 0.06 dB/MHz/Gy based on each Gy in the linear range of 4-44 Gy. Ultrasonic parameters were measured in the gel samples at 5, 15, and 25 ºC after 0-60 Gy irradiation in 2 Gy steps to determine the sensitivity of the ultrasonic properties to temperature. The measurements show that readings at 25 °C have a higher sensitivity than that at 5 and 15 °C. Thus, with an increase of 20 °C, the speed of sound increased 28 and 66 m/s before irradiation and with 60 Gy absorbed dose, respectively. Moreover, the attenuation coefficient decreased 2.50 dB/MHz before irradiation and increased 2.70 dB/MHz with 60 Gy absorbed dose. Conclusion: Acoustic properties of MAGIC-f gel, determined by measurements of speed of sound and ultrasonic broadband attenuation, indicate the ability of this technique in reading of absorbed dose. Maximum sensitivity of reading time and temperature of MAGIC-f gel were 24 hours after irradiation and 25 °C, respectively

Keywords

  1. Khan FM. The physics of radiation therapy. 4th ed. Philadelphia, PA: Lippincott Williams & Wilkins; 2012. p. 415-6.
  2. Gore JC, Kang YS, Schulz RJ. Measurement of radiation dose distributions by nuclear magnetic resonance (NMR) imaging. Phys Med Biol 1984; 29(10): 1189-97.
  3. Maryanski MJ, Schulz RJ, Ibbott GS, Gatenby JC, Xie J, Horton D, et al. Magnetic resonance imaging of radiation dose distributions using a polymer-gel dosimeter. Phys Med Biol 1994; 39(9): 1437-55.
  4. News from Yale Medical SchoolandHarvard Cyclotron Laboratory. Three dimensional dose distributions for 160 MeV protons using magnetic resonance imaging of the tissue-equivalent BANG polymer-gel dosimeter [Online]. [cited 1994 Jun]; Available fromL URL: http://www.ptcog.ch/archive/particle_news/particles_13_1994.pdf
  5. Maryanski MJ, Gore JC, Kennan RP, Schulz RJ. NMR relaxation enhancement in gels polymerized and cross-linked by ionizing radiation: A new approach to 3D dosimetry by MRI. Magnetic Resonance Imaging 1993; 11(2): 253-8.
  6. De DY, De WC, Van DB, Derycke S, Mersseman B, De GW, et al. Validation of MR-based polymer gel dosimetry as a preclinical three-dimensional verification tool in conformal radiotherapy. Magn Reson Med 2000; 43(1): 116-25.
  7. Haraldsson P, Back SA, Magnusson P, Olsson LE. Dose response characteristics and basic dose distribution data for a polymerization-based dosemeter gel evaluated using MR. Br J Radiol 2000; 73(865): 58-65.
  8. De DY, Hurley C, Venning A, Vergote K, Mather M, Healy BJ, et al. A basic study of some normoxic polymer gel dosimeters. Phys Med Biol 2002; 47(19): 3441-63.
  9. Baldock C, Burford RP, Billingham N, Wagner GS, Patval S, Badawi RD, et al. Experimental procedure for the manufacture and calibration of polyacrylamide gel (PAG) for magnetic resonance imaging (MRI) radiation dosimetry. Phys Med Biol 1998; 43(3): 695-702.
  10. Baldock C, Rintoul L, Keevil SF, Pope JM, George GA. Fourier transform Raman spectroscopy of polyacrylamide gels (PAGs) for radiation dosimetry. Phys Med Biol 1998; 43(12): 3617-27.
  11. Sittig M. Handbook of toxic and hazardous chemicals and carcinogens. 2nd ed. New Jersey, NJ: Noyes Publications; 1985. p. 41-4.
  12. McJury M, Oldham M, Cosgrove VP, Murphy PS, Doran S, Leach MO, et al. Radiation dosimetry using polymer gels: methods and applications. Br J Radiol 2000; 73(873): 919-29.
  13. Fong PM, Keil DC, Does MD, Gore JC. Polymer gels for magnetic resonance imaging of radiation dose distributions at normal room atmosphere. Phys Med Biol 2001; 46(12): 3105-13.
  14. De DY, Vergote K, Claeys C, De WC. The fundamental radiation properties of normoxic polymer gel dosimeters: a comparison between a methacrylic acid based gel and acrylamide based gels. Phys Med Biol 2006; 51(3): 653-73.
  15. Hurley C, Venning A, Baldock C. A study of a normoxic polymer gel dosimeter comprising methacrylic acid, gelatin and tetrakis (hydroxymethyl) phosphonium chloride (MAGAT). Appl Radiat Isot 2005; 63(4): 443-56.
  16. Luci JJ, Whitney HM, Gore JC. Optimization of MAGIC gel formulation for three-dimensional radiation therapy dosimetry. Phys Med Biol 2007; 52(10): N241-N248.
  17. Adinehvand K, Zahmatkesh M, Aghamiri M, Akhlaghpour S, Bagheri S. Verification of dose rate and energy dependence of MAGICA polymer gel dosimeter with electron beams. Iran J Radiat Res 2008; 6(1): 31-6.
  18. Fernandes JP, Pastorello BF, de Araujo DB, Baffa O. Formaldehyde increases MAGIC gel dosimeter melting point and sensitivity. Phys Med Biol 2008; 53(4): N53-N58.
  19. Mather ML, De DY, Whittaker AK, Simon GP, Rutgers R, Baldock C. Investigation of ultrasonic properties of PAG and MAGIC polymer gel dosimeters. Phys Med Biol 2002; 47(24): 4397-409.
  20. Marini G, Pavan T, Baggio A, Carneiro A. Doppler images of heterogeneous gel dosimeter phantom by multi-frequency vibration. Rio de Janeiro, Brazil: Health Care Exchanges; 2011. p. 347-9.
  21. Chu KC, Jordan KJ, Battista JJ, Van DJ, Rutt BK. Polyvinyl alcohol-Fricke hydrogel and cryogel: two new gel dosimetry systems with low Fe3+ diffusion. Phys Med Biol 2000; 45(4): 955-69.
  22. Hilts M, Audet C, Duzenli C, Jirasek A. Polymer gel dosimetry using x-ray computed tomography: a feasibility study. Phys Med Biol 2000; 45(9): 2559-71.
  23. Hilts M, Jirasek A, Duzenli C. Effects of gel composition on the radiation induced density change in PAG polymer gel dosimeters: a model and experimental investigations. Phys Med Biol 2004; 49(12): 2477-90.
  24. Trapp JV, Back SA, Lepage M, Michael G, Baldock C. An experimental study of the dose response of polymer gel dosimeters imaged with x-ray computed tomography. Phys Med Biol 2001; 46(11): 2939-51.
  25. Trapp JV, Michael G, De DY, Baldock C. Attenuation of diagnostic energy photons by polymer gel dosimeters. Phys Med Biol 2002; 47(23): 4247-58.
  26. Oldham M, Siewerdsen JH, Shetty A, Jaffray DA. High resolution gel-dosimetry by optical-CT and MR scanning. Med Phys 2001; 28(47): 1436-45.
  27. Novotny J, Jr., Spevacek V, Dvorak P, Novotny J, Cechak T. Energy and dose rate dependence of BANG-2 polymer-gel dosimeter. Med Phys 2001; 28(11): 2379-86.
  28. De DY, Venning A, Hurley C, Healy BJ, Baldock C. Dose-response stability and integrity of the dose distribution of various polymer gel dosimeters. Phys Med Biol 2002; 47(14): 2459-70.
  29. Karlsson A, Gustavsson H, Mansson S, McAuley KB, Back SA. Dose integration characteristics in normoxic polymer gel dosimetry investigated using sequential beam irradiation. Phys Med Biol 2007; 52(15): 4697-706.
  30. Crescenti RA, Bamber JC, Bush NL, Webb S. Characterization of dose-dependent Young's modulus for a radiation-sensitive polymer gel. Phys Med Biol 2009; 54(4): 843-57.
  31. Mather ML, Whittaker AK, Baldock C. Ultrasound evaluation of polymer gel dosimeters. Phys Med Biol 2002; 47(9): 1449-58.
  32. Atkins TJ, Humphrey VF, Duck FA, Tooley MA. Investigation of ultrasonic properties of MAGIC gels for pulse-echo gel dosimetry. J Phys: Conf Ser 2010; 250: 1-5.
  33. Njeh CF, Blake GM. Calcaneal quantitative ultrasound devices. In: Fuerst T, Genant HK, Gluer CC, Hans D, Njeh CF, Editors. Quantitative ultrasound: assessment of osteoporosis and bone status. Boca Raton, FL: Taylor & Francis; 1999. p. 109-24.
  34. Crescenti RA, Bamber JC, Oberai AA, Barbone PE, Richter JP, Rivas C, et al. Quantitative ultrasonic elastography for gel dosimetry. Ultrasound Med Biol 2010; 36(2): 268-75.
  35. Maryanski MJ, Zastavker YZ, Gore JC. Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels: II. Optical properties of the BANG polymer gel. Phys Med Biol 1996; 41(12): 2705-17.