Document Type : Case Report
Authors
- Saeedeh Delavari 1
- Pouria Espahbudi 2
- Neda Fayazi 3
- Mehran Akbari 4
- Ramin Ronasi 4
- Hanieh Raghimi 5
- Sam Zeraatiannejad Davani 6, 7
1 Department of Health Information Technology, Khomein University of Medical Sciences, Khomein, Iran
2 Student Research Committee, Iran University of Medical Sciences, Tehran, Iran
3 Department of Nursing, School of Nursing and Midwifery, Saveh University of Medical Sciences, Saveh, Iran
4 Department of Clinical Sciences, Khomein University of Medical Sciences, Khomein, Iran
5 Department of Internal Medicine, School of Medicine, Golestan University of Medical Sciences, Gorgan, Iran
6 Department of Cardiovascular Surgery, Iran University of Medical Sciences, Tehran, Iran
7 Department of Surgery, Faculty Member of Northwestern University, Northwestern Memorial Hospital, Canning Thoracic Institution, Illinois State, Chicago, United States of America
Abstract
Introduction: Fluorescein angiography is considered a diagnostic imaging technique that involves injecting fluorescein into the patient's bloodstream and then capturing images of the dye as it passes through the patient's blood vessels.
Case report: The present study is a case report of a 62-year-old male with type II diabetes who was admitted due to an infectious diabetic foot and signs of gangrene. The patient underwent angiography for the preparation of amputation. However, the angiography revealed a severe three-vessel disease, making him a candidate for coronary artery bypass graft. In this surgery, before initiating grafting and during thoracoscopy, fluorescein was injected into the intravascular arteries to locate the graft sites and for real-time visualization of coronary arteries. After the procedure, the patient’s hemodynamic status was stabilized, and he was discharged in a desirable condition.
Conclusion: The importance of intraoperative fluorescence imaging in increasing the success rate of minimally invasive coronary artery bypass graft outcomes and reducing the patient’s complications after discharge.
Keywords
Main Subjects
- Schmidt-RioValle J, Abu Ejheisheh M, Membrive-Jiménez MJ, Suleiman-Martos N, Albendín-García L, Correa-Rodríguez M, et al. Quality of life after coronary artery bypass surgery: a systematic review and meta-analysis. Int J Environ Res Public Health 2020;17(22):8439. doi:10.3390/ijerph17228439
- Ricardi F, Reibaldi M, Bandello F, Borrelli E. Fluorescein angiography. In: Chhablani J, ed. Retinal and Choroidal Vascular Diseases of the Eye. Academic Press; 2024. p. 71-9. doi:10.1016/b978-0-443-15583-3.00005-6
- Yang RQ, Lou KL, Wang PY, Gao YY, Zhang YQ, Chen M, et al. Surgical navigation for malignancies guided by near‐infrared‐II fluorescence imaging. Small Methods 2021;5(3): e2001066. doi:10.1002/smtd.202001066
- Waseda K, Ako J, Hasegawa T, Shimada Y, Ikeno F, Ishikawa T, et al. Intraoperative fluorescence imaging system for on-site assessment of off-pump coronary artery bypass graft. JACC Cardiovasc Imaging 2009;2(5):604-12. doi:10.1016/j. jcmg.2008.12.028
- Spadaccio C, Nenna A, Corrado D, Glenn C, Panza A, Vester R, et al. Use of indocyanine green (ICG) to assess myocardial perfusion and territorial distribution of vein grafts implanted on coronary arteries in an ex-vivo porcine model. A potential adjunct to assist revascularization strategies and training in coronary artery bypass grafting. Rev Cardiovasc Med 2025;26(1):25778. doi:10.31083/rcm25778
- McGinn JT Jr, Usman S, Lapierre H, Pothula VR, Mesana TG, Ruel M. Minimally invasive coronary artery bypass grafting: dual-center experience in 450 consecutive patients. Circulation 2009;120(11 Suppl): S78-84. doi:10.1161/ circulationaha.108.840041
- Detter C, Russ D, Kersten JF, Reichenspurner H, Wipper S. Qualitative angiographic and quantitative myocardial perfusion assessment using fluorescent cardiac imaging during graded coronary artery bypass stenosis. Int J Cardiovasc Imaging 2018;34(2):159-67. doi:10.1007/s10554-017-1212-1
- Desai ND, Miwa S, Kodama D, Koyama T, Cohen G, Pelletier MP, et al. A randomized comparison of intraoperative indocyanine green angiography and transit-time flow measurement to detect technical errors in coronary bypass grafts. J Thorac Cardiovasc Surg 2006;132(3):585-94. doi:10.1016/j.jtcvs.2005.09.061
- Ng CS, Ong BH, Chao YK, Wright GM, Sekine Y, Wong I, et al. Use of indocyanine green fluorescence imaging in thoracic and esophageal surgery. Ann Thorac Surg 2023;115(4):1068- 76. doi:10.1016/j.athoracsur.2022.06.061
- Nakajima T, Iba Y, Shibata T, Ohkawa A, Kawaharada N. Identification of a dissection site in the internal thoracic artery using fluorescence imaging: a case report. Cureus 2024;16(2): e55199. doi:10.7759/cureus.55199
- Cheng J, Sun LY, Liu J, Zhang CW. Indocyanine green fluorescence imaging for spleen preservation in laparoscopic splenic artery aneurysm resection: a case report. World J Gastrointest Surg 2022;14(7):714-9. doi:10.4240/wjgs.v14. i7.714
- Wagner T, Mustafov O, Hummels M, Grabenkamp A, Thomas MN, Schiffmann LM, et al. Imaged guided surgery during arteriovenous malformation of gastrointestinal stromal tumor using hyperspectral and indocyanine green visualization techniques: a case report. World J Clin Cases 2023;11(23):5530- 7. doi:10.12998/wjcc.v11.i23.5530
- Mehdorn M, Ebel S, Köhler H, Gockel I, Jansen-Winkeln B. Hyperspectral imaging and indocyanine green fluorescence angiography in acute mesenteric ischemia: a case report on how to visualize intestinal perfusion. Int J Surg Case Rep 2021;82:105853. doi:10.1016/j.ijscr.2021.105853